推荐星级:
  • 1
  • 2
  • 3
  • 4
  • 5

电磁超声检测系统中消除电磁干扰电路的设计

更新时间:2020-07-24 21:45:33 大小:321K 上传用户:守着阳光1985查看TA发布的资源 标签:电磁超声检测系统 下载积分:5分 评价赚积分 (如何评价?) 打赏 收藏 评论(0) 举报

资料介绍

电磁超声技术作为一种非接触式探伤技术在恶劣工况条件下具有广泛的应用前景,然而其发射电路产生的以共模噪声为主的脉冲电磁干扰会影响检测电路的接收效果进而产生误检。针对该问题,设计了消除电磁干扰的硬件电路,构建了具有高速、高共模抑制比、高输入阻抗以及低噪等特点的复合仪表放大器。电路用高速低噪双通道ADA4817-2作为输入增益级放大器,后接高共模抑制性能的AD8429仪表运放,提高了电路对噪声的抑制能力。在工况下进行测试,结果表明该电路能够实现共模噪声的有效消除。

As a type of industrial non-contact detection method, electromagnetic acoustic transducer( EMAT) has a broad application prospect in harsh industrial conditions. However,the pulse electromagnetic interference( EMI),mainly the common-mode noise,produced by its emission circuit will affect the detection circuit and then generate false detection. Aiming at this problem,the hardware circuit is designed to eliminate the EMI. The composite instrumentation amplifier with the characteristics of high speed,high common mode rejection ratio,high input impedance, and low noise is designed. The high-speed circuit utilizes the low noise dual channel ADA4817-2 as the input gain amplifier and uses a high common mode rejectio...

部分文件列表

文件名 大小
电磁超声检测系统中消除电磁干扰电路的设计.pdf 321K

【关注B站账户领20积分】

全部评论(0)

暂无评论

上传资源 上传优质资源有赏金

  • 打赏
  • 30日榜单

推荐下载