ABBACSM1-04伺服驱动器安装说明书
资料介绍
ABB伺服驱动器安装说明书
Never work on the drive, the braking chopper circuit, the motor cable or the motor when input power is applied to the drive. After disconnecting input power, always wait for 5
minutes to let the intermediate circuit capacitors discharge before you start workingon the drive, control cabling, motor or motor cable. Even when input power is not applied to the drive, externally supplied control circuits may carry dangerous voltages. Always ensure by measuring that no voltage is actually present.
A rotating permanent magnet motor can generate a dangerous voltage. Lock the motor shaft mechanically before connecting a permanent magnet motor to the drive, and before doing any work on a drive system connected to a permanent magnet motor.
The ACSM1-04 is an IP20 (UL open type)
drive to be used in a heated, indoor controlled environment. The drive must be installed in clean air according to enclosure classification. Cooling air must be clean,free from corrosive materials and electrically