通常采用在电源侧加装有源电力滤波器(APF)来滤除电网中的谐波和无功电流,使其仅提供基波分量。APF主电路中的功率器件存在死区时间,将导致输出电流波形失真,输出电压与期望电压产生偏差,从而对APF的补偿性能产生消极影响,降低装置补偿效果。在此首先定性分析了死区效应的形成机理及对系统补偿性能的影响,然后提出了一种新型的基于电流反馈的死区补偿策略。通过对Matlab仿真研究及研制的70 kVAAPF进行实际的工程验证,证明了该方法的可行性和有效性。

Installing active power filter(APF) in power side is commonly used to remove harmonics and reactive current of supply,making it provide fundamental components.There exsits dead-time of the power switching devices in main circuit,which will lead output current waveform to distort,and has a negative effect on output compensation current and reduces APF's compensation performance.The dead-time effect's formation mechanism and influence of compensation performance qualitatively are analyzed,and then a new dead-time compensation strategy is proposed based on current feedback.The proposal is proved to be effective and feasible by Matlab simulation and actual project verification of 70 kVA APF.