脉冲中子测井仪器采用伽马闪烁探测器将伽马射线转化为随机脉冲电信号,输出信号上升快,下降缓,容易造成信号堆砌,不利于峰值采样。为了准确采集脉冲电信号的峰值,需要对仪器前端探测器输出信号进行放大和滤波整形。电路设计中采用了电荷放大器、基线恢复电路,零极相消电路以及CR-RC等滤波整形电路。通过对输出信号计算分析,采用PSPICE对电路进行调试仿真,最终进行实际电路测试,检测结果实现了信号的放大和滤波整形处理。该电路满足仪器多功能测量模式对信号的需求,结合元器件选型,电路具有耐高温、响应速度快,线性度好、稳定度高等优点。

With the help of the gamma rays scintillation detector,pulsed neutron well logging instrument can convert gamma rays into randomly pulsed phase signal,the output signal rises fast and falls slowly,so it is easy to cause the signal stack while not conducive to the peak value order to accurately capture the peak pulse signals,we need to amplify and filter the instrument front-end detector output circuit is adopted in the design of chargesensitive preamplifier,baseline restorer,pole-zero cancellation and CR-RC pulse ough calculation and analysis of the output signal,PSPICE simulation of the circuit debugging is used for the actual circuit testing to ...