X射线光声成像的信号检测与仿真

更新时间:2020-07-07 04:45:08 大小:3M 上传用户:六3无线电查看TA发布的资源 标签:信号检测 下载积分:5分 评价赚积分 (如何评价?) 打赏 收藏 评论(0) 举报

资料介绍

通过理论仿真和实验检测结果,分析由医用直线加速器产生的X射线照射铅块所产生的光声信号特性.使用光电二极管搭建一个光电检测电路,检测到医用直线加速器所产生的脉冲X射线的光脉冲宽度约为4μs.采用K-wave工具包仿真分析脉冲宽度为几个微秒的光脉冲所产生的光声信号.搭建了一个光声信号检测系统,对比分析分别使用Olypus V301商用探头与自制的PZT-4陶瓷换能器时的检测性能.结果表明,两款探头都检测到了光声信号,V301商用探头检测结果与理论仿真波形一致性较好,但信噪比低,而本研究设计的PZT-4检测灵敏度高,但检测到的信号波形与理论仿真结果偏差较大.两款探头在检测脉冲宽度为4μs的X射线脉冲所产生的声信号时都存在不足,为更好的检测该光声信号,需设计一款中心频率在70 kHz附近、带宽较宽、检测灵敏度较高的探头.

The aim of this paper is to analyze the characteristics of the photo-acoustic(PA) signal,which is induced by irradiating the lead with X-ray from a medical linear accelerator. Related theoretical simulations and experiments are done. A photodiode detection circuit is put up to detect the width of X-ray pulses,which is about 4 μs. The K-wave software is used to simulate and analyze the PA signal generated by X-ray whose pulse width was several microseconds. We also put up a single element photo-acoustic signal acquisition system and carry out the comparative experiments with Olympus...